Product Description
Overview
Universal Integrated Furnace Control offers universal compatibility and diagnostics. It replaces a large number of furnace control models in single-stage warm air furnaces. Uses 120Vac hot surface igniter. Includes instructions and special wire harnesses for easy replacement.
Features
- ⢠Cross reference and wire harnesses provided for simple replacement over 195 existing furnace controls.
- Main burner ignition using a 120V hot surface igniter.
- Flame rectification circuit to monitor flame presence.
- Monitoring of system pressure switch, high temperature limit, and rollout functions.
- Appliance operation/safety requirements controlled via microprocessor.
- Controls circulating fan motor based on appliance requirements, in response to a conventional low voltage thermostat.
- LED system status, performance and diagnostic indication.
- Twinning capability
Product Specifications
- Application
- Single stage warm air furnaces
- Frequency
- 60 Hz
- Operating Humidity Range (% RH)
- 0% to 95% non-condensing
- Operating Temperature Range (F)
- -40 F to +175 F
- Operating Temperature Range (C)
- -40 C to +79 C
- Flame Failure Response Time (sec)
- 2 Seconds max @ 1µA
- PrePurge
- 30 seconds
- PostPurge
- 15 seconds
- Cool Fan On Delay
- 5 seconds
- Cool Fan Off Delay
- 0 or 60 seconds
- Line Voltage
- 120 Vac (97-132 Vac)
- Low Voltage
- 24V (18-30 Vac)
- Igniter Current
- 5 A resistive @ 120VAC
- Thermostat Anticipator Setting
- (Stage 1 only) 100mA
- HSI Warmup Time
- 17/27 or 30/30 seconds
- Trial For Ignition
- 4, 6, or 8 seconds
- Interpurge
- 60 seconds
- Ignition Trials
- Three, two tries if flame is not sensed
- Number of LEDs
- 3
- Heat On Fan Delay
- 30 or 60 seconds
- Heat Off Fan Delay
- 60, 90, 120, or 180 Seconds
- Gas Control Used With
- Any 24Vac redundant, direct ignition gas control rated at 1.5A or less. Honeywell VR8205 recommended.
- Cooling Contactor Used With
- Any 24Vac contactor rated at 1.0A or less
- Induced Draft Blower Load
- 2.2FLA / 25LRA max @120Vac
- Ciculator Load
- 14.5FLA / 25LRA max @120Vac
- Type of Fan Used With
- Standard Induction-Type Circulating Fan
Reviews